{"_buckets": {"deposit": "c7165ea8-afc5-4ff3-9f70-5aed1ab01105"}, "_deposit": {"created_by": 15, "id": "8181", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "8181"}, "status": "published"}, "_oai": {"id": "oai:mie-u.repo.nii.ac.jp:00008181", "sets": ["639"]}, "author_link": ["20424", "20425", "20426", "20427", "20428"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1995-11-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "591", "bibliographicPageEnd": "4030", "bibliographicPageStart": "4024", "bibliographicVolumeNumber": "61", "bibliographic_titles": [{"bibliographic_title": "日本機械学會論文集. B編"}]}]}, "item_10001_description_19": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Improvement of the generation power in micro-hydraulic turbines is shown in the range of low flow rate and low head using a new inverter generation system. The generation power can be obtained down to very low flow rate and head using the new inverter generation system with variable rotational speed control, where a water turbine connot produce the electric power in a normal constant-speed-control system. Experiments were carried out using a practical micro-hydraulic turbine with 2 kW output and variable rotational speed in a forest on the mountain, Mie University. The total efficiency is kept at a high value even in the very low partial load area. Compared with the constant speed control, the generation power is improved over 20 percent by varying the rotational speed.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本機械学会"}]}, "item_10001_relation_42": {"attribute_name": "関係URI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "http://ci.nii.ac.jp/naid/110002403017/"}]}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "社団法人日本機械学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_10001_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00187441", "subitem_source_identifier_type": "NCID"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5016", "subitem_source_identifier_type": "PISSN"}]}, "item_10001_subject_21": {"attribute_name": "日本十進分類法", "attribute_value_mlt": [{"subitem_subject": "540", "subitem_subject_scheme": "NDC"}]}, "item_10001_text_25": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_text_value": "Studies on High Performance Generation System of Micro-hydraulic Turbine in Low Flow Rate and Lew Head"}]}, "item_10001_text_70": {"attribute_name": "資源タイプ(三重大)", "attribute_value_mlt": [{"subitem_text_value": "Journal Article / 学術雑誌論文"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "清水, 幸丸", "creatorNameLang": "ja"}, {"creatorName": "Shimizu, Yukimaru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "20424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "前田, 太佳夫", "creatorNameLang": "ja"}, {"creatorName": "Maeda, Takao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "20425", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤原, 秀成", "creatorNameLang": "ja"}, {"creatorName": "Fujiwara, Hidenari", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "20426", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田, 実", "creatorNameLang": "ja"}, {"creatorName": "Takada, Minoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "20427", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大塚, 史郎", "creatorNameLang": "ja"}, {"creatorName": "Ohtsuka, Shiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "20428", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-02-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "40A6596.pdf", "filesize": [{"value": "603.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 603200.0, "url": {"label": "40A6596.pdf", "url": "https://mie-u.repo.nii.ac.jp/record/8181/files/40A6596.pdf"}, "version_id": "f5138901-aa22-45dd-b61c-8cca06d20fba"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Fluid Machinery", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Water Turbine", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Low Flow Rate", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Low Head", "subitem_subject_scheme": "Other"}, {"subitem_subject": "New Inverter Generation System", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Variable Rotational Speed Control", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "新インバータ発電システムによるマイクロ水力発電システムの高性能化に関する研究 : 可変落差・可変流量下での高性能発電", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "新インバータ発電システムによるマイクロ水力発電システムの高性能化に関する研究 : 可変落差・可変流量下での高性能発電", "subitem_title_language": "ja"}]}, "item_type_id": "10001", "owner": "15", "path": ["639"], "permalink_uri": "http://hdl.handle.net/10076/8184", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2008-02-18"}, "publish_date": "2008-02-18", "publish_status": "0", "recid": "8181", "relation": {}, "relation_version_is_last": true, "title": ["新インバータ発電システムによるマイクロ水力発電システムの高性能化に関する研究 : 可変落差・可変流量下での高性能発電"], "weko_shared_id": -1}
新インバータ発電システムによるマイクロ水力発電システムの高性能化に関する研究 : 可変落差・可変流量下での高性能発電
http://hdl.handle.net/10076/8184
http://hdl.handle.net/10076/81840ee7e4c5-72f8-4765-b07f-a7731f993886
名前 / ファイル | ライセンス | アクション |
---|---|---|
40A6596.pdf (603.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-02-18 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 新インバータ発電システムによるマイクロ水力発電システムの高性能化に関する研究 : 可変落差・可変流量下での高性能発電 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Fluid Machinery | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Water Turbine | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Low Flow Rate | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Low Head | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | New Inverter Generation System | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Variable Rotational Speed Control | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
清水, 幸丸
× 清水, 幸丸× 前田, 太佳夫× 藤原, 秀成× 高田, 実× 大塚, 史郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Improvement of the generation power in micro-hydraulic turbines is shown in the range of low flow rate and low head using a new inverter generation system. The generation power can be obtained down to very low flow rate and head using the new inverter generation system with variable rotational speed control, where a water turbine connot produce the electric power in a normal constant-speed-control system. Experiments were carried out using a practical micro-hydraulic turbine with 2 kW output and variable rotational speed in a forest on the mountain, Mie University. The total efficiency is kept at a high value even in the very low partial load area. Compared with the constant speed control, the generation power is improved over 20 percent by varying the rotational speed. | |||||
書誌情報 |
日本機械学會論文集. B編 巻 61, 号 591, p. 4024-4030, 発行日 1995-11-25 |
|||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0387-5016 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00187441 | |||||
権利 | ||||||
権利情報 | 社団法人日本機械学会 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
日本十進分類法 | ||||||
主題Scheme | NDC | |||||
主題 | 540 | |||||
その他のタイトル | ||||||
Studies on High Performance Generation System of Micro-hydraulic Turbine in Low Flow Rate and Lew Head | ||||||
出版者 | ||||||
出版者 | 日本機械学会 | |||||
関係URI | ||||||
関連名称 | http://ci.nii.ac.jp/naid/110002403017/ | |||||
資源タイプ(三重大) | ||||||
Journal Article / 学術雑誌論文 |