{"created":"2023-06-19T11:41:53.239999+00:00","id":10846,"links":{},"metadata":{"_buckets":{"deposit":"c31611ae-6125-45ed-b5cf-874fc58c7af8"},"_deposit":{"created_by":13,"id":"10846","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"10846"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00010846","sets":["515:753:754:755"]},"author_link":["27143","27144","27145","27146","27147"],"item_1706510172288":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Chao, Chen","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ohyama, Wataru","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Wakabayashi, Tetsushi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kimura, Fumitaka","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sekioka, Kiyotsugu","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-10-08","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"30","bibliographicPageStart":"27","bibliographic_titles":[{"bibliographic_title":"Proceedings of the First International Workshop on Regional Innovation Studies : Biomedical Engineering (IWRIS2009)","bibliographic_titleLang":"en"}]}]},"item_3_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We propose a new methodology for motion tracking of local myocardial tissue on M-mode echocardiograms. This methodology is applicable to the quantitative assessment of myocardial performance in clinics. The Mmode echocardiogram is widely used in clinics to measure diagnostic indexes like thickening and thinning of myocardial muscle layers. To measure such indexes, doctors are required to track myocardial motion manually, however the tracking of myocardial motion by hand is tedious and time-consuming process. Our proposed method is able to track the myocardial motion on M-mode echocardiograms automatically by employing DP-based optimization. In this report we present the proposed method.","subitem_description_type":"Abstract"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"October8, 2009. Media Hall, Mie University, Tsu, Mie, Japan","subitem_description_type":"Other"},{"subitem_description":"Proceedings of the First International Workshop on Regional Innovation Studies : Biomedical Engineering (IWRIS2009)","subitem_description_type":"Other"}]},"item_3_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Graduate School of Regional Innovation Studies, Mie University"}]},"item_3_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Conference Paper / 会議発表論文"}]},"item_3_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-20"}],"displaytype":"detail","filename":"60G13599.pdf","filesize":[{"value":"2.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"60G13599.pdf","url":"https://mie-u.repo.nii.ac.jp/record/10846/files/60G13599.pdf"},"version_id":"9e228444-a7d3-40df-abd9-409b608cb719"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Myocardial Motion Tracking","subitem_subject_scheme":"Other"},{"subitem_subject":"Ultrasonic Imaging","subitem_subject_scheme":"Other"},{"subitem_subject":"Echocardiography","subitem_subject_scheme":"Other"},{"subitem_subject":"Dynamic Programming","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Semi-automatic noninvasive assessment of local myocardial motion using M-mode echocardiogram","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Semi-automatic noninvasive assessment of local myocardial motion using M-mode echocardiogram","subitem_title_language":"en"}]},"item_type_id":"3","owner":"13","path":["755"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-07-01"},"publish_date":"2010-07-01","publish_status":"0","recid":"10846","relation_version_is_last":true,"title":["Semi-automatic noninvasive assessment of local myocardial motion using M-mode echocardiogram"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2024-01-30T00:50:51.025458+00:00"}