{"created":"2023-06-19T11:42:12.532146+00:00","id":11312,"links":{},"metadata":{"_buckets":{"deposit":"bebb236e-80aa-49e5-bb9e-474657cf4773"},"_deposit":{"created_by":16,"id":"11312","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"11312"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00011312","sets":["334:608:618:833"]},"author_link":[],"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-03-25","bibliographicIssueDateType":"Issued"}}]},"item_7_date_granted_59":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2016-03-25"}]},"item_7_degree_grantor_57":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"三重大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"14101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_7_degree_name_56":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)"}]},"item_7_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PURPOSE. We studied whether pupil size affects the flicker electroretinograms (ERGs) recorded by RETeval, a new mydriasis-free full-field flicker ERG system. METHODS. We studied 10 healthy subjects. The RETeval manufacturer claims that the system delivers a constant flash retinal illuminance by adjusting the flash luminance to compensate for changes in the pupil size. Two experiments were performed. First, the flicker ERG was recorded every 3 minutes after the instillation of mydriatics. Second, the flicker ERG was recorded while the subjects wore soft contact lenses with two different artificial pupil sizes. RESULTS. The first experiment showed that as pupil size increased, the amplitudes of the fundamental component of the flicker ERG did not change significantly, but the implicit times of the fundamental component were significantly prolonged for larger pupil sizes. There was a significant positive correlation between the pupillary area and implicit time of the fundamental component (r 1/4 0.93, P < 0.001). The second experiment showed that the implicit times of the fundamental component in the flicker ERG were significantly longer with larger artificial pupil. CONCLUSIONS. The results suggest that the effective retinal illuminance of the stimulus delivered by the RETeval system decreases for large pupil sizes. However, in most clinical testing situations, patients’ undilated pupils will likely be sufficiently small to fall within the range for which the system delivers a stimulus of constant retinal illuminance.","subitem_description_type":"Abstract"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"本文 / Department of Ophthalmology, Mie University Graduate School of Medicine","subitem_description_type":"Other"},{"subitem_description":"7p","subitem_description_type":"Other"}]},"item_7_dissertation_number_60":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医学第1760号"}]},"item_7_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"三重大学"}]},"item_7_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1167/iovs.14-16349","subitem_relation_type_select":"DOI"}}]},"item_7_relation_37":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://iovs.arvojournals.org/article.aspx?articleid=2319724"}]}]},"item_7_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc."}]},"item_7_text_31":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ミエダイガク"}]},"item_7_text_63":{"attribute_name":"ノート","attribute_value_mlt":[{"subitem_text_value":"Investigative Ophthalmology & Visual Science, 56 (6), 2015, pp. 3684-3690 ISSN : 1552-5783 に掲載"}]},"item_7_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Doctoral Dissertation / 博士論文"}]},"item_7_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kato, Kumiko","creatorNameLang":"en"},{"creatorName":"カトウ, クミコ","creatorNameLang":"ja-Kana"},{"creatorName":"加藤, 久美子","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-07-04"}],"displaytype":"detail","filename":"2015DM023.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"2015DM023","objectType":"fulltext","url":"https://mie-u.repo.nii.ac.jp/record/11312/files/2015DM023.pdf"},"version_id":"2d715340-0dc8-4cb0-adcb-7c85b8a96eb5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"electroretinogram (ERG)","subitem_subject_scheme":"Other"},{"subitem_subject":"flicker ERG","subitem_subject_scheme":"Other"},{"subitem_subject":"pupil","subitem_subject_scheme":"Other"},{"subitem_subject":"implicit time","subitem_subject_scheme":"Other"},{"subitem_subject":"mydriasis","subitem_subject_scheme":"Other"},{"subitem_subject":"RETeval","subitem_subject_scheme":"Other"},{"subitem_subject":"fundamental component","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Effect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System","subitem_title_language":"en"}]},"item_type_id":"7","owner":"16","path":["833"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-07-04"},"publish_date":"2017-07-04","publish_status":"0","recid":"11312","relation_version_is_last":true,"title":["Effect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-11-06T04:42:46.447987+00:00"}