{"created":"2023-06-19T11:42:18.548132+00:00","id":11466,"links":{},"metadata":{"_buckets":{"deposit":"aa8aa844-fe20-43c2-b0d9-93059337f504"},"_deposit":{"created_by":16,"id":"11466","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"11466"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00011466","sets":["334:608:618:843"]},"author_link":[],"item_7_alternative_title_19":{"attribute_name":"その他の言語のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Quantifying size of retinal hemorrhage in BRVO","subitem_alternative_title_language":"en"}]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-12-21","bibliographicIssueDateType":"Issued"}}]},"item_7_date_granted_59":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2016-12-21"}]},"item_7_degree_grantor_57":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"三重大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"14101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_7_degree_name_56":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)"}]},"item_7_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose: To describe a method of quantifying the size of the retinal hemorrhages in branch retinal vein occlusion (BRVO), and to determine the inter-rater and intra-rater reliabilities of these measurements. Methods: Thirty-five fundus photographs from 35 consecutive eyes with BRVO were studied. The fundus images were analyzed with Power-Point® software, and a grid of 14 squares was laid over the fundus image. Raters were asked to judge the percentage of each of the 14 squares that was covered by the hemorrhages, and the average of the 14 squares was taken to be the relative size of the retinal hemorrhage. Results: Inter-rater reliability between three raters was higher when a grid with 14 squares was used (intra-class correlation coefficient (ICC), 0.96) than that when a box with no grid was used (ICC, 0.78). Intra-rater reliability, which was calculated by the retinal hemorrhage area measured on two different days was also higher (ICC, 0.97) than that with no grid (ICC, 0.86). Inter-rater reliability for five fundus pictures with poor image quality was also good when a grid with 14 squares was used (ICC, 0.88). Conclusions: Although our method is subjective, excellent inter-rater and intra-rater reliabilities indicate that this method can be adapted for clinical use.","subitem_description_type":"Abstract"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"本文 / Department of Ophthalmology, Mie University Graduate School of Medicine","subitem_description_type":"Other"},{"subitem_description":"24p","subitem_description_type":"Other"}]},"item_7_dissertation_number_60":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医学第1808号"}]},"item_7_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"三重大学"}]},"item_7_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1155/2016/1960190","subitem_relation_type_select":"DOI"}}]},"item_7_text_31":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ミエダイガク"}]},"item_7_text_63":{"attribute_name":"ノート","attribute_value_mlt":[{"subitem_text_value":"Journal of Ophthalmology, 2016: Article ID 1960190, p. 8, 2016 に掲載"}]},"item_7_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Doctoral Dissertation / 博士論文"}]},"item_7_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Takashima, Yuko","creatorNameLang":"en"},{"creatorName":"タカシマ, ユウコ","creatorNameLang":"ja-Kana"},{"creatorName":"髙嶌, 祐布子","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-07"}],"displaytype":"detail","filename":"2016DM014.pdf","filesize":[{"value":"849.1 kB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"2016DM014","objectType":"fulltext","url":"https://mie-u.repo.nii.ac.jp/record/11466/files/2016DM014.pdf"},"version_id":"b3414af1-017c-4a8c-ab8a-56ad1fd2376c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"retinal hemorrhage","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"branch retinal vein occlusion","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"quantification","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"inter-rater reliability","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"intra-rater reliability","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Method of Quantifying Size of Retinal Hemorrhages in Eyes with Branch Retinal Vein Occlusion Using 14 Square Grid : Inter-rater and Intra-rater Reliability","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Method of Quantifying Size of Retinal Hemorrhages in Eyes with Branch Retinal Vein Occlusion Using 14 Square Grid : Inter-rater and Intra-rater Reliability","subitem_title_language":"en"}]},"item_type_id":"7","owner":"16","path":["843"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-11-07"},"publish_date":"2017-11-07","publish_status":"0","recid":"11466","relation_version_is_last":true,"title":["Method of Quantifying Size of Retinal Hemorrhages in Eyes with Branch Retinal Vein Occlusion Using 14 Square Grid : Inter-rater and Intra-rater Reliability"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-11-02T05:34:14.783371+00:00"}