{"created":"2023-06-19T11:42:18.885131+00:00","id":11474,"links":{},"metadata":{"_buckets":{"deposit":"aa9b11c5-89ff-4276-8b8c-32bd247e8146"},"_deposit":{"created_by":16,"id":"11474","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"11474"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00011474","sets":["334:608:618:843"]},"author_link":[],"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-03-24","bibliographicIssueDateType":"Issued"}}]},"item_7_date_granted_59":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2017-03-24"}]},"item_7_degree_grantor_57":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"三重大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"14101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_7_degree_name_56":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)"}]},"item_7_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose The purpose of this study was to evaluate the usefulness of a computer-aided diagnosis (CAD) scheme for improving the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images. Methods The database included 97 ultrasonographic images with hypoechoic areas: 48 benign cases [benign lesion with benign mammary tissue or fibrocystic disease (n = 20), fibroadenoma (n = 11), and intraductal papilloma (n = 17)] and 49 malignant cases [ductal carcinoma in situ (n = 17) and invasive ductal carcinoma (n = 32)]. Seven clinicians, three expert breast surgeons, and four general surgeons participated in the observer study. They were asked their confidence level concerning the possibility of malignancy in all 97 cases with and without the use of the CAD scheme. Receiver operating characteristic (ROC) analysis was performed to evaluate the usefulness of the CAD scheme. Results The areas under the ROC curve (AUC) improved for all observers when they used the CAD scheme and increased from 0.649 to 0.783 (P = 0.0167). Notably, the AUC for the general surgeon group increased from 0.625 to 0.793 (P = 0.045). Conclusions This study showed that the performance of clinicians to diagnose non-mass lesions appearing as hypoechoic areas on breast ultrasonographic images was improved by the use of a CAD scheme.","subitem_description_type":"Abstract"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"本文 / Department of Breast Surgery, Mie University Hospital","subitem_description_type":"Other"},{"subitem_description":"21p","subitem_description_type":"Other"}]},"item_7_dissertation_number_60":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医学第1818号"}]},"item_7_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"三重大学"}]},"item_7_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1007/s10396-016-0718-9","subitem_relation_type_select":"DOI"}}]},"item_7_text_31":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ミエダイガク"}]},"item_7_text_63":{"attribute_name":"ノート","attribute_value_mlt":[{"subitem_text_value":"Journal of Medical Ultrasonics, 43(3), 2016, pp. 387-394 ISSN:1346-4523 に掲載"}]},"item_7_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Doctoral Dissertation / 博士論文"}]},"item_7_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Shibusawa, Mai","creatorNameLang":"en"},{"creatorName":"シブサワ, マイ","creatorNameLang":"ja-Kana"},{"creatorName":"澁澤, 麻衣","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-11-07"}],"displaytype":"detail","filename":"2016DM025.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"2016DM025","objectType":"fulltext","url":"https://mie-u.repo.nii.ac.jp/record/11474/files/2016DM025.pdf"},"version_id":"c455941d-6d6c-418b-8cfc-0cb08ddf87f7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Computer-aided diagnosis","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Breast ultrasonography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Breast non-mass lesions","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"The usefulness of a computer-aided diagnosis scheme for improving the performance of clinicians to diagnose non-mass lesions on breast ultrasonographic images","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The usefulness of a computer-aided diagnosis scheme for improving the performance of clinicians to diagnose non-mass lesions on breast ultrasonographic images","subitem_title_language":"en"}]},"item_type_id":"7","owner":"16","path":["843"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-11-07"},"publish_date":"2017-11-07","publish_status":"0","recid":"11474","relation_version_is_last":true,"title":["The usefulness of a computer-aided diagnosis scheme for improving the performance of clinicians to diagnose non-mass lesions on breast ultrasonographic images"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-11-02T05:34:33.017297+00:00"}