{"created":"2023-06-19T11:42:37.437134+00:00","id":11872,"links":{},"metadata":{"_buckets":{"deposit":"59b339d4-0d14-4c45-bfcf-70e77d54eafd"},"_deposit":{"created_by":16,"id":"11872","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"11872"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00011872","sets":["334:608:618:857"]},"author_link":[],"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-12-20","bibliographicIssueDateType":"Issued"}}]},"item_7_date_granted_59":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2017-12-20"}]},"item_7_degree_grantor_57":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"三重大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"14101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_7_degree_name_56":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)"}]},"item_7_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Methods: Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. Results: A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg・hr/dL with 88.2% sensitivity and 81.5% specificity. Conclusion: We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.","subitem_description_type":"Abstract"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"本文 / Department of Diabetes, Metabolism and Endocrinology, Mie University Graduate School of Medicine","subitem_description_type":"Other"},{"subitem_description":"10p","subitem_description_type":"Other"}]},"item_7_dissertation_number_60":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医学第1870号"}]},"item_7_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"三重大学"}]},"item_7_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.4093/dmj.2017.41.4.265","subitem_relation_type_select":"DOI"}}]},"item_7_text_31":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ミエダイガク"}]},"item_7_text_63":{"attribute_name":"ノート","attribute_value_mlt":[{"subitem_text_value":"Diabetes Metab J 2017;41:265-274, ISSN:2233-6079 に掲載"}]},"item_7_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Doctoral Dissertation / 博士論文"}]},"item_7_version_type_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Uemura, Mei","creatorNameLang":"en"},{"creatorName":"ウエムラ, メイ","creatorNameLang":"ja-Kana"},{"creatorName":"上村, 明","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-28"}],"displaytype":"detail","filename":"2017DM012.pdf","filesize":[{"value":"229.6 kB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"2017DM012.pdf","objectType":"fulltext","url":"https://mie-u.repo.nii.ac.jp/record/11872/files/2017DM012.pdf"},"version_id":"a5e94d5d-6d8b-4cb5-8407-35c1d20b4aec"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Continuous glucose monitoring","subitem_subject_scheme":"Other"},{"subitem_subject":"Diabetes mellitus","subitem_subject_scheme":"Other"},{"subitem_subject":"Glucose area under the curve","subitem_subject_scheme":"Other"},{"subitem_subject":"Hyperglycemia","subitem_subject_scheme":"Other"},{"subitem_subject":"Nocturnal blood","subitem_subject_scheme":"Other"},{"subitem_subject":"glucose","subitem_subject_scheme":"Other"},{"subitem_subject":"Post-prandial blood glucose","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients","subitem_title_language":"en"}]},"item_type_id":"7","owner":"16","path":["857"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-02-28"},"publish_date":"2018-02-28","publish_status":"0","recid":"11872","relation_version_is_last":true,"title":["Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2023-11-02T00:18:20.798312+00:00"}