{"created":"2024-01-31T01:58:38.844555+00:00","id":2000331,"links":{},"metadata":{"_buckets":{"deposit":"542863ec-20c6-4565-8abd-db76e926d3c2"},"_deposit":{"created_by":16,"id":"2000331","owners":[16],"pid":{"revision_id":0,"type":"depid","value":"2000331"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:02000331","sets":["334:608:618:1694066935734"]},"author_link":[],"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-09-25","bibliographicIssueDateType":"Issued"}}]},"item_7_date_granted_59":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2023-09-25"}]},"item_7_degree_grantor_57":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"三重大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"14101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_7_degree_name_56":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)"}]},"item_7_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spinecho T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE T1-BB VWI. Twenty cervical carotid plaque lesions in 19 patients with a plaque contrast ratio of > 1.3 compared to adjacent muscle were studied. Using the mean voxel value for the adjacent muscle multiplied by 1.3 as a threshold value, the semiautomated software exclusively segmented and measured the HSP volume. Manual and semiautomated HSP volumes were well correlated (r = 0.965). Regarding reproducibility, the inter-rater ICC was 0.959 (bias: 24.63, 95% limit of agreement: −96.07, 146.35) for the manual method and 0.998 (bias: 15.2, 95% limit of agreement: −17.83, 48.23) for the semiautomated method, indicating improved reproducibility by the semiautomated method compared to the manual method. The time required for semiautomated segmentation was significantly shorter than that of manual segmentation times (81.7 ± 7.8 s versus 189.5 ± 49.6 s; p < 0.01). The results obtained in this study demonstrate that the semiautomated segmentation method allows for reliable assessment of the HSP volume in patients with carotid plaque lesions, with reduced time and effort for the analysis.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_7_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"本文/Department of Radiology, Mie University Hospital, Tsu 514-8507, Mie, Japan","subitem_description_type":"Other"},{"subitem_description":"9p","subitem_description_type":"Other"}]},"item_7_dissertation_number_60":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲医学第2204号"}]},"item_7_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"三重大学"}]},"item_7_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3390/diagnostics12041014","subitem_relation_type_select":"DOI"}}]},"item_7_text_31":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"ミエダイガク"}]},"item_7_text_63":{"attribute_name":"ノート","attribute_value_mlt":[{"subitem_text_value":"Diagnostics 2022, 12(4): 1014に掲載"}]},"item_7_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Doctoral Dissertation / 博士論文"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Inoue, Katsuhiro","creatorNameLang":"en"},{"creatorName":"イノウエ, カツヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"井上, 勝博","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available"}],"displaytype":"detail","filename":"2023DM0908.pdf","filesize":[{"value":"870 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"label":"2023DM0908","objectType":"fulltext","url":"https://mie-u.repo.nii.ac.jp/record/2000331/files/2023DM0908.pdf"},"version_id":"82dd793d-361a-4a83-9796-4e15eae8cdd9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"carotid artery","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"unstable carotid plaque","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"semiautomated segmentation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"3D TSE T1-weighted black-blood vessel wall imaging","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study","subitem_title_language":"en"}]},"item_type_id":"7","owner":"16","path":["1694066935734"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-02-06"},"publish_date":"2024-02-06","publish_status":"0","recid":"2000331","relation_version_is_last":true,"title":["Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study"],"weko_creator_id":"16","weko_shared_id":-1},"updated":"2024-02-06T01:22:57.264137+00:00"}