{"created":"2023-06-19T11:37:26.270982+00:00","id":4742,"links":{},"metadata":{"_buckets":{"deposit":"49eecba9-7d0d-4819-ad81-b9a3ff697f14"},"_deposit":{"created_by":13,"id":"4742","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"4742"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00004742","sets":["366:367:368:372"]},"author_link":["34946","34947","34948","34949"],"item_4_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1979-12-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"9","bibliographicPageStart":"1","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"Research reports of the Faculty of Engineering, Mie University"}]}]},"item_4_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_4_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The method of the calibration of Laser Doppler Velocimeter is described in this paper. The velocity measurements of the revolving disc and the water flow are carried out. It is ascertained that the lower velocities and the instantaneous velocities can be measured, and the various components of the velocity can also be found by revolving the intersecting plane of two laser beams. The experimental results agree well with the theoretical ones.","subitem_description_type":"Abstract"}]},"item_4_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Faculty of Engineering, Mie University"}]},"item_4_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-6208","subitem_source_identifier_type":"PISSN"}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00816341","subitem_source_identifier_type":"NCID"}]},"item_4_text_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"レーザー・ドップラー流速計の検定に関する研究"}]},"item_4_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper / 紀要論文"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kuzuhara, Sadao","creatorNameLang":"en"},{"creatorName":"葛原, 定郎","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"34946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimizu, Yukimaru","creatorNameLang":"en"},{"creatorName":"清水, 幸丸","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"34947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sugino, Koichi","creatorNameLang":"en"},{"creatorName":"杉野, 公一","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"34948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Yukitaka","creatorNameLang":"en"},{"creatorName":"早川, 幸孝","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"34949","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Studies on the Calibration of Laser Doppler Velocimeter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Studies on the Calibration of Laser Doppler Velocimeter","subitem_title_language":"en"}]},"item_type_id":"4","owner":"13","path":["372"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-03-15"},"publish_date":"2018-03-15","publish_status":"0","recid":"4742","relation_version_is_last":true,"title":["Studies on the Calibration of Laser Doppler Velocimeter"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-10-05T01:50:13.255172+00:00"}