{"created":"2023-06-19T11:37:36.785764+00:00","id":4987,"links":{},"metadata":{"_buckets":{"deposit":"0956a444-ce61-4e0f-beab-5cc592e27cdd"},"_deposit":{"created_by":13,"id":"4987","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"4987"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00004987","sets":["366:367:368:388"]},"author_link":["35391","35392"],"item_4_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1995-12-21","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"23","bibliographicPageStart":"11","bibliographicVolumeNumber":"20","bibliographic_titles":[{"bibliographic_title":"Research reports of the Faculty of Engineering, Mie University"}]}]},"item_4_description_14":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_4_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this paper, we propose a new prototype model of micro catheter with active guide wire that has two bending degrees of freedom. The design and fabrication method of this micro active catheters (MAC) are described. Prototype models are 3Fr, 4Fr, 6Fr (1Fr=1/3mm) in diameter and consist of catheter tube and active guide wire with ICPF (Ionic Conducting Polymer Film) actuator on its front end as the servo actuator. The bending characteristics of the MAC are measured by application of electricity in physiological saline solution. We also modeled this MAC for characteristic evaluation. Experimetal results show that the model of the active catheter is reasonable for practical applications. By using simulators (whose conditions are similar to those of a body cavity), we carried out simulation experiments \"in vitro\". The experimental results indicate that the proposed MAC is applicable to intracavity operations.","subitem_description_type":"Abstract"}]},"item_4_publisher_30":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Faculty of Engineering, Mie University"}]},"item_4_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-6208","subitem_source_identifier_type":"PISSN"}]},"item_4_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00816341","subitem_source_identifier_type":"NCID"}]},"item_4_text_18":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_text_language":"ja","subitem_text_value":"マイクロ能動ガイドワイヤーカテーテルシステム"}]},"item_4_text_65":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper / 紀要論文"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Guo, Shuxiang","creatorNameLang":"en"},{"creatorName":"郭, 書祥","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nakamura, Tatsuya","creatorNameLang":"en"},{"creatorName":"中村, 達也","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Micromachine","subitem_subject_scheme":"Other"},{"subitem_subject":"Robot","subitem_subject_scheme":"Other"},{"subitem_subject":"Catheter","subitem_subject_scheme":"Other"},{"subitem_subject":"Minimum invasive surgery","subitem_subject_scheme":"Other"},{"subitem_subject":"Ionic conducting polymer film actuator (ICPF Actuator)","subitem_subject_scheme":"Other"},{"subitem_subject":"Experiments \"in Vitro\"","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Micro Catheter System with Active Guide Wire","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Micro Catheter System with Active Guide Wire","subitem_title_language":"en"}]},"item_type_id":"4","owner":"13","path":["388"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-03-15"},"publish_date":"2018-03-15","publish_status":"0","recid":"4987","relation_version_is_last":true,"title":["Micro Catheter System with Active Guide Wire"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-10-05T06:33:47.859590+00:00"}