{"created":"2023-06-19T11:39:58.192712+00:00","id":8220,"links":{},"metadata":{"_buckets":{"deposit":"ab40c300-8d8c-480d-9252-a6c2cdb98a07"},"_deposit":{"created_by":15,"id":"8220","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"8220"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00008220","sets":["366:638:639"]},"author_link":["20649","20650","20651"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-05-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"717","bibliographicPageEnd":"1700","bibliographicPageStart":"1695","bibliographicVolumeNumber":"72","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集. C編"}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"For the 3 D measurements using the images taken with cameras, it is necessary to know the values of the camera's intrinsic parameters, such as the image coordinates of principal point, i.e., the projection of the projection center to the image plane, the principal distance between the principal point and the projection center, and the image distortion coefficients. In the 3 D measurements, we need to estimate the calibration accuracy of the camera's intrinsic parameters. Therefore, the authors examined a two-plane calibration method with respect to the calibration accuracy. Paying attention of the fact that the image coordinate measurement errors of the fiducial points propagate to the calibrated intrinsic parameter values, and the magnitude of the error could be formulized according to the setup of the fiducial points, the authors presented many useful relationships between the calibration accuracies and the fiducial point setups.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_10001_relation_42":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://ci.nii.ac.jp/naid/110004738311/"}]}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187463","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5024","subitem_source_identifier_type":"PISSN"}]},"item_10001_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"530","subitem_subject_scheme":"NDC"}]},"item_10001_text_25":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_text_value":"Relationships between the Camera Calibration Accuracy and the Imaging Condition"}]},"item_10001_text_70":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Journal Article / 学術雑誌論文"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"藤本, 貴史","creatorNameLang":"ja"},{"creatorName":"FUJIMOTO, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"野村, 由司彦","creatorNameLang":"ja"},{"creatorName":"NOMURA, Yoshihiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"張, 滌利","creatorNameLang":"ja"},{"creatorName":"ZHANG, Dili","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-18"}],"displaytype":"detail","filename":"72A6711.pdf","filesize":[{"value":"564.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"72A6711.pdf","url":"https://mie-u.repo.nii.ac.jp/record/8220/files/72A6711.pdf"},"version_id":"b037cd0e-732e-4085-9201-a194b7aa68d2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Camera Parameter Calibration","subitem_subject_scheme":"Other"},{"subitem_subject":"Fiducial Point","subitem_subject_scheme":"Other"},{"subitem_subject":"Imaging Condition","subitem_subject_scheme":"Other"},{"subitem_subject":"Accuracy","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"カメラパラメータ較正における較正精度と撮像条件","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"カメラパラメータ較正における較正精度と撮像条件","subitem_title_language":"ja"}]},"item_type_id":"10001","owner":"15","path":["639"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2008-03-13"},"publish_date":"2008-03-13","publish_status":"0","recid":"8220","relation_version_is_last":true,"title":["カメラパラメータ較正における較正精度と撮像条件"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2023-10-13T02:24:23.114218+00:00"}