{"created":"2023-06-19T11:40:02.691912+00:00","id":8326,"links":{},"metadata":{"_buckets":{"deposit":"295ad5cd-beed-4bdc-ab4d-90e6bcd6d03c"},"_deposit":{"created_by":15,"id":"8326","owners":[15],"pid":{"revision_id":0,"type":"depid","value":"8326"},"status":"published"},"_oai":{"id":"oai:mie-u.repo.nii.ac.jp:00008326","sets":["366:638:639"]},"author_link":[],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1988-09-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"505","bibliographicPageEnd":"2645","bibliographicPageStart":"2639","bibliographicVolumeNumber":"54","bibliographic_titles":[{"bibliographic_title":"日本機械学會論文集. B編 = Transactions of the Japan Society of Mechanical Engineers. B"}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The paper describes small scale bio-mass electric power plant. Saw dust is used for the fuel. Gas reactor is developed and improved to increase the gasifying efficiency. The engine exhaust heat is exchanged to hot water and hot air. The hot air is used to dry the lumber. As the result, total efficiency of this electric power-heat co-generation system is eminently improved.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_10001_relation_42":{"attribute_name":"関係URI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://ci.nii.ac.jp/naid/110002401539"}]}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187441","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5016","subitem_source_identifier_type":"PISSN"}]},"item_10001_subject_21":{"attribute_name":"日本十進分類法","attribute_value_mlt":[{"subitem_subject":"530","subitem_subject_scheme":"NDC"}]},"item_10001_text_25":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_text_value":"Bio-mass Gas Co-generation System of Electric Power and Engine Exhaust Heat Utilizing Saw Dust"}]},"item_10001_text_70":{"attribute_name":"資源タイプ(三重大)","attribute_value_mlt":[{"subitem_text_value":"Journal Article / 学術雑誌論文"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"清水, 幸丸","creatorNameLang":"ja"},{"creatorName":"Shimizu, Yukimaru","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"鈴木, 信夫","creatorNameLang":"ja"},{"creatorName":"Suzuki, Nobuo","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"黒川, 静夫","creatorNameLang":"ja"},{"creatorName":"Kurokawa, Shizuo","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"法貴, 誠","creatorNameLang":"ja"},{"creatorName":"Hoki, Makoto","creatorNameLang":"en"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-18"}],"displaytype":"detail","filename":"40A7145.pdf","filesize":[{"value":"752.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"40A7145.pdf","url":"https://mie-u.repo.nii.ac.jp/record/8326/files/40A7145.pdf"},"version_id":"3932157e-41b3-422d-bc10-68730789d41a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Wood","subitem_subject_scheme":"Other"},{"subitem_subject":"Bio-mass","subitem_subject_scheme":"Other"},{"subitem_subject":"Saw dust","subitem_subject_scheme":"Other"},{"subitem_subject":"Gas engine","subitem_subject_scheme":"Other"},{"subitem_subject":"Small scale electric power plant","subitem_subject_scheme":"Other"},{"subitem_subject":"Electro-heat co-generation system","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"おがくずガス化発電とコ・ジェネレーションシステムに関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"おがくずガス化発電とコ・ジェネレーションシステムに関する研究","subitem_title_language":"ja"}]},"item_type_id":"10001","owner":"15","path":["639"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-03-01"},"publish_date":"2010-03-01","publish_status":"0","recid":"8326","relation_version_is_last":true,"title":["おがくずガス化発電とコ・ジェネレーションシステムに関する研究"],"weko_creator_id":"15","weko_shared_id":-1},"updated":"2023-10-13T06:25:28.151118+00:00"}