WEKO3
アイテム
{"_buckets": {"deposit": "93edd83d-1956-4466-989d-bd73af55da09"}, "_deposit": {"created_by": 13, "id": "5497", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "5497"}, "status": "published"}, "_oai": {"id": "oai:mie-u.repo.nii.ac.jp:00005497", "sets": ["418"]}, "author_link": ["11490"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-02-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "23", "bibliographicPageStart": "21", "bibliographicVolumeNumber": "23", "bibliographic_titles": [{"bibliographic_title": "技術職員による技術報告集"}]}]}, "item_4_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "X線や電子線によるミクロンやナノレベルの測定では様々な要因が結果に影響を及ぼす。今回、光電子分光分析注1装置(XPS)により2種類の材料、4 種類の試料固定方法で測定を行い、測定結果を比較した。また、この結果比較から生じた違いの考察を行ったので報告する。*注1・・・光電子分光分析では試料表面にX 線を照射することで試料から発生する光電子のエネルギー値から構成元素や化学結合状態を知ることができる。", "subitem_description_type": "Abstract"}]}, "item_4_publisher_30": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "三重大学技術発表会実行委員会"}]}, "item_4_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1348-1991", "subitem_source_identifier_type": "PISSN"}]}, "item_4_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12131001", "subitem_source_identifier_type": "NCID"}]}, "item_4_text_65": {"attribute_name": "資源タイプ(三重大)", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper / 紀要論文"}]}, "item_4_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "梅田, 直明", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "11490", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-02-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "40C17249.pdf", "filesize": [{"value": "272.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 272700.0, "url": {"label": "40C17249.pdf", "url": "https://mie-u.repo.nii.ac.jp/record/5497/files/40C17249.pdf"}, "version_id": "4ff4f876-2e75-4b8d-bd60-c33282e3fcd1"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "試料固定方法の違いによる影響について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "試料固定方法の違いによる影響について", "subitem_title_language": "ja"}]}, "item_type_id": "4", "owner": "13", "path": ["418"], "permalink_uri": "http://hdl.handle.net/10076/14345", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2015-03-02"}, "publish_date": "2015-03-02", "publish_status": "0", "recid": "5497", "relation": {}, "relation_version_is_last": true, "title": ["試料固定方法の違いによる影響について"], "weko_shared_id": -1}
試料固定方法の違いによる影響について
http://hdl.handle.net/10076/14345
http://hdl.handle.net/10076/14345fb8f2c50-f7b5-47f1-ab71-b386938ce19c
名前 / ファイル | ライセンス | アクション |
---|---|---|
40C17249.pdf (272.7 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-02 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 試料固定方法の違いによる影響について | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
梅田, 直明
× 梅田, 直明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | X線や電子線によるミクロンやナノレベルの測定では様々な要因が結果に影響を及ぼす。今回、光電子分光分析注1装置(XPS)により2種類の材料、4 種類の試料固定方法で測定を行い、測定結果を比較した。また、この結果比較から生じた違いの考察を行ったので報告する。*注1・・・光電子分光分析では試料表面にX 線を照射することで試料から発生する光電子のエネルギー値から構成元素や化学結合状態を知ることができる。 | |||||
書誌情報 |
技術職員による技術報告集 巻 23, p. 21-23, 発行日 2015-02-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1348-1991 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12131001 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | 三重大学技術発表会実行委員会 | |||||
資源タイプ(三重大) | ||||||
Departmental Bulletin Paper / 紀要論文 |