WEKO3
アイテム
MPC-grafted highly cross-linked polyethylene liners retrieved from short-term total hip arthroplasty: Further evidences for the unsuitability of the MPC method
http://hdl.handle.net/10076/00019694
http://hdl.handle.net/10076/00019694489db513-dc71-48b8-be87-10b4eb6b213f
名前 / ファイル | ライセンス | アクション |
---|---|---|
2020DM0340 (6.5 MB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2021-06-29 | |||||||||||
タイトル | ||||||||||||
タイトル | MPC-grafted highly cross-linked polyethylene liners retrieved from short-term total hip arthroplasty: Further evidences for the unsuitability of the MPC method | |||||||||||
言語 | en | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | alkoxyl radical | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | oxidation | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | phosphorylcholine | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | polyethylene | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | total hip arthroplasty | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||||||||
資源タイプ | doctoral thesis | |||||||||||
アクセス権 | ||||||||||||
アクセス権 | open access | |||||||||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||||||||
著者 |
細井, 敬
× 細井, 敬
|
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | An analysis is presented of four short-term retrieved highly crosslinked polyethylene (HXLPE) hip liners grafted with 2-methacryloyloxyethyl phosphorylcholine (MPC) on their bearing surfaces, which were recently commercialized as a new generation of artificial hip joints. Straightforward evidences by X-ray photoelectron spectroscopy (XPS) confirmed that the MPC layer peeled off on the bearing surface of all shortterm liners in both main wear and nonwear zones. Analyses by Fourier-transform infrared spectroscopy with attenuated total reflection assessed the extent of surface oxidation and revealed the type of oxidative species. Electron spin resonance analyses, which compared retrievals and as-received samples, revealed the presence of different species of alkoxyl CO• radicals. This study suggests that MPC grafts on polyethylene do not offer any additional protection from oxidation and can delaminate prematurely after short-term in vivo exposure. | |||||||||||
言語 | en | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | 本文/Department of Orthopedic Surgery, Graduate School of Medicine, Mie University, Tsu City, Mie, Japan | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | 11p | |||||||||||
書誌情報 |
発行日 2021-03-25 |
|||||||||||
DOI | ||||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | 10.1002/jbm.b.34617 | |||||||||||
フォーマット | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | application/pdf | |||||||||||
著者版フラグ | ||||||||||||
出版タイプ | VoR | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||
出版者 | ||||||||||||
出版者 | 三重大学 | |||||||||||
出版者(ヨミ) | ||||||||||||
値 | ミエダイガク | |||||||||||
学位名 | ||||||||||||
学位名 | 博士(医学) | |||||||||||
学位授与機関 | ||||||||||||
学位授与機関識別子Scheme | kakenhi | |||||||||||
学位授与機関識別子 | 14101 | |||||||||||
学位授与機関名 | 三重大学 | |||||||||||
学位授与年月日 | ||||||||||||
学位授与年月日 | 2021-03-25 | |||||||||||
学位授与番号 | ||||||||||||
学位授与番号 | 甲医学第2065号 | |||||||||||
ノート | ||||||||||||
値 | Journal of Biomedical Materials Research Part B Applied Biomaterials 2020; 108(7) :2857-2867に掲載 | |||||||||||
資源タイプ(三重大) | ||||||||||||
値 | Doctoral Dissertation / 博士論文 |