Abscopal 効果の効果的な照射/ワクチン最適注射臓器の探索
http://hdl.handle.net/10076/00020877
http://hdl.handle.net/10076/00020877f4c65769-5c4e-4f8a-9373-43cdf40abdeb
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 報告書 / Research Paper(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2022-11-24 | |||||||||||
タイトル | ||||||||||||
タイトル | Abscopal 効果の効果的な照射/ワクチン最適注射臓器の探索 | |||||||||||
言語 | ja | |||||||||||
タイトル | ||||||||||||
タイトル | Exploratory Optimization of Organs for Radiotherapy or Cancer Vaccination by Abscopal Effect | |||||||||||
言語 | en | |||||||||||
言語 | ||||||||||||
言語 | jpn | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | abscopal effect | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 遠隔効果 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 抗PD-1抗体 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 放射線治療 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 定位照射 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 小動物照射装置 | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18ws | |||||||||||
資源タイプ | research report | |||||||||||
著者 |
渡辺, 隆
× 渡辺, 隆
|
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | 転移巣局所に放射線療法を行うことで照射野から離れた部位のがん病変が縮小することを abscocal effectと呼ぶが、特に免疫チェックポイント阻害剤併用で期待できる。小動物を用いた基礎研究が行われておらず、原理は未解明。多臓器好転移がん細胞株を用いて、胎生期に各組織に入った組織常在マクロファージが抗原提示すると仮説し、血中から流入する異なる種類の単球を遮断することで、証明を計画した。肝臓のみを照射する装置を作製したが、マウスが全て死亡したため、まず後脚のみを外に出して他を遮蔽した8匹同時照射装置を作製した。黒色腫の実験に留まり、大腸・乳がんでの肝・肺・脳照射効果の違いを示すに至らなかった。 | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | Abscopal effect is tumor reduction effect outside the radiation field. Immune checkpoint inhibitors enhance the effect because PD-L1 is overexpressed in irradiated tumors. The exact mechanism of the effect has not been yet elucidated. The biggest obstacle to disclosure is no local irradiation devices for small animals developed. We first made irradiation devices using lead shield having windows for liver or one lobe of liver. However, all the mice that received a single dose of radiation with various doses were dead. Therefore, we next made a device using a 50mL-conical tubes covered with lead tunnels, where holes were drilled for stretching one lower limb so that 8 mice could be simultaneously irradiated in the same condition. The device worked well but the “second” melanoma on the upper flank opposite to the lower limb did not show any obvious abscopal effects despite of the optimized schedule of an anti-PD-1 antibody administration starting in advance of radiation initiation. | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | 2017年度~2020年度科学研究費補助金(基盤研究(C))研究成果報告書 | |||||||||||
書誌情報 |
発行日 2021-05-26 |
|||||||||||
フォーマット | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | application/pdf | |||||||||||
著者版フラグ | ||||||||||||
出版タイプ | VoR | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||
出版者 | ||||||||||||
出版者 | 三重大学 | |||||||||||
出版者(ヨミ) | ||||||||||||
ミエダイガク | ||||||||||||
科研費番号 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | 17K10473 | |||||||||||
資源タイプ(三重大) | ||||||||||||
Kaken / 科研費報告書 |