{"_buckets": {"deposit": "7a2ca671-40eb-4f3b-bb20-1b3bc41983e8"}, "_deposit": {"created_by": 13, "id": "6446", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "6446"}, "status": "published"}, "_oai": {"id": "oai:mie-u.repo.nii.ac.jp:00006446", "sets": ["518"]}, "author_link": ["15039", "15040", "15041", "15042", "15043", "15044", "15045", "15046"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "78", "bibliographicPageStart": "75", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Second International Workshop on Regional Innovation Studies : (IWRIS2010)"}]}]}, "item_4_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In ophthalmology, the needs of retina diagnosis using optical coherence tomography (OCT) have been growing and the automatic measurement of a retinal thickness and its quantitative evaluation are desired for the diagnosis of retinal diseases. Previously, the automatic measurement methods of the retinal thickness have been reported for retinal OCT im-ages. However, the conventional methods have a disadvantage that the methods extracted the retinal border lines intermit-tently for OCT images with any damages. In this paper, we propose a new automatic measurement method of a retinal thickness in OCT image. The method employs a new dynamic contour model (“One Directional Active Net (ODAN)”) to extract two retinal border lines, and the thickness is defined from Inner Limiting Membrane (ILM) to Retinal Pigment Epithelium (RPE). ODAN employs a new energy function to extract the retinal border lines exactly and the energy function moves all nodes of ODAN to one direction only to minimize the total energy repeatedly. The energy function consists of the conformity characteristics energy of image to fit a border and the internal strain energy between the two dimensional nodes to arrange smoothly the position of each node. We confirmed the usefulness of the ODAN by the experimental results for normal and retinal disease OCT images. The proposed method is useful as the basic method for the detection of retinal diseas-es.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_30": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Graduate School of Regional Innovation Studies, Mie University"}]}, "item_4_text_65": {"attribute_name": "資源タイプ(三重大)", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper / 紀要論文"}]}, "item_4_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamakawa, Ai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15039", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kodama, Dai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15040", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuruoka, Shinji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15041", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawanaka, Hiroharu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15042", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takase, Haruhiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15043", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uji, Yukitaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsubara, Hisashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15045", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuyama, Fumio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15046", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-02-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "60C15240.pdf", "filesize": [{"value": "488.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 488300.0, "url": {"label": "60C15240.pdf", "url": "https://mie-u.repo.nii.ac.jp/record/6446/files/60C15240.pdf"}, "version_id": "3151d1ca-5957-4960-8ab4-e74525e31c74"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "inner limiting membrane", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "retinal pigment epi-thelium", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "optical coherence tomography", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "active net", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Extraction Method of Retinal Border Lines for Optical Coherence Tomography by Using One Directional Active Net", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Extraction Method of Retinal Border Lines for Optical Coherence Tomography by Using One Directional Active Net", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "13", "path": ["518"], "permalink_uri": "http://hdl.handle.net/10076/11666", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-11-08"}, "publish_date": "2011-11-08", "publish_status": "0", "recid": "6446", "relation": {}, "relation_version_is_last": true, "title": ["Extraction Method of Retinal Border Lines for Optical Coherence Tomography by Using One Directional Active Net"], "weko_shared_id": -1}
Extraction Method of Retinal Border Lines for Optical Coherence Tomography by Using One Directional Active Net
http://hdl.handle.net/10076/11666
http://hdl.handle.net/10076/11666dca3eaa2-ebdd-4de3-bb3b-9f99253ffec7
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-08 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Extraction Method of Retinal Border Lines for Optical Coherence Tomography by Using One Directional Active Net | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | inner limiting membrane | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | retinal pigment epi-thelium | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | optical coherence tomography | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | active net | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
Yamakawa, Ai
× Yamakawa, Ai× Kodama, Dai× Tsuruoka, Shinji× Kawanaka, Hiroharu× Takase, Haruhiko× Uji, Yukitaka× Matsubara, Hisashi× Okuyama, Fumio |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In ophthalmology, the needs of retina diagnosis using optical coherence tomography (OCT) have been growing and the automatic measurement of a retinal thickness and its quantitative evaluation are desired for the diagnosis of retinal diseases. Previously, the automatic measurement methods of the retinal thickness have been reported for retinal OCT im-ages. However, the conventional methods have a disadvantage that the methods extracted the retinal border lines intermit-tently for OCT images with any damages. In this paper, we propose a new automatic measurement method of a retinal thickness in OCT image. The method employs a new dynamic contour model (“One Directional Active Net (ODAN)”) to extract two retinal border lines, and the thickness is defined from Inner Limiting Membrane (ILM) to Retinal Pigment Epithelium (RPE). ODAN employs a new energy function to extract the retinal border lines exactly and the energy function moves all nodes of ODAN to one direction only to minimize the total energy repeatedly. The energy function consists of the conformity characteristics energy of image to fit a border and the internal strain energy between the two dimensional nodes to arrange smoothly the position of each node. We confirmed the usefulness of the ODAN by the experimental results for normal and retinal disease OCT images. The proposed method is useful as the basic method for the detection of retinal diseas-es. | |||||
書誌情報 |
Proceedings of the Second International Workshop on Regional Innovation Studies : (IWRIS2010) 号 2, p. 75-78, 発行日 2011-10-01 |
|||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Graduate School of Regional Innovation Studies, Mie University | |||||
資源タイプ(三重大) | ||||||
Departmental Bulletin Paper / 紀要論文 |