{"_buckets": {"deposit": "348cf49b-bf4e-4cea-91ed-dc43d5cd09cc"}, "_deposit": {"created_by": 13, "id": "6448", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "6448"}, "status": "published"}, "_oai": {"id": "oai:mie-u.repo.nii.ac.jp:00006448", "sets": ["518"]}, "author_link": ["15055", "15056", "15057", "15058", "15059", "15060", "15061", "15062", "15063"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "86", "bibliographicPageStart": "83", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Second International Workshop on Regional Innovation Studies : (IWRIS2010)"}]}]}, "item_4_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Optical Coherence Tomography (OCT) image\nis very useful to the diagnosis and the follow up evaluation of\nthe response to treatment using either medication or surgery,\nand it is an emerging medical imaging technology for performing\nhigh resolution cross-sectional images. In ophthalmology,\nthis technology can provide 3D images of retinal architecture,\nand it is useful for identifying, monitoring, quantitatively assessing\nof retinal disease. Evaluations of quantitative information\non retinal architecture especially on the abnormal parts\nare importance to diagnosis the degree of abnormal and to\nconsider a treatment approach. This research proposes a new\nextraction method for the abnormal regions of retina from 3D\nOCT images using the combination of digital image processing\nmethods. Our research objectives are extracting the border\nline of abnormal parts of 3D OCT retinal images. This research\nuses 128 2D OCT images about one retina of a patient,\nwhich is specified the part of macular by an ophthalmologist.\nWe can extract some border lines of abnormal parts in OCT\nretinal images by using image processing techniques.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_30": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Graduate School of Regional Innovation Studies, Mie University"}]}, "item_4_text_65": {"attribute_name": "資源タイプ(三重大)", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper / 紀要論文"}]}, "item_4_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mohd, Fadzil bin Abdul Kadir", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakawa, Ai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kodama, Dai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuruoka, Shinji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawanaka, Hiroharu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takase, Haruhiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uji, Yukitaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsubara, Hisashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15062", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuyama, Fumio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15063", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-02-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "60C15242.pdf", "filesize": [{"value": "545.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 545000.0, "url": {"label": "60C15242.pdf", "url": "https://mie-u.repo.nii.ac.jp/record/6448/files/60C15242.pdf"}, "version_id": "639fc5d4-d159-4b07-9ce5-4b8e0c4c690a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Optical coherence tomography (OCT)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image processing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image diagnosis system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "retinal layer structure", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "13", "path": ["518"], "permalink_uri": "http://hdl.handle.net/10076/11668", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-11-09"}, "publish_date": "2011-11-09", "publish_status": "0", "recid": "6448", "relation": {}, "relation_version_is_last": true, "title": ["Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image"], "weko_shared_id": -1}
Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image
http://hdl.handle.net/10076/11668
http://hdl.handle.net/10076/1166809868a9f-0005-4c83-a842-15bbf1392da6
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-09 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Optical coherence tomography (OCT) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | image processing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | image diagnosis system | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | retinal layer structure | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
Mohd, Fadzil bin Abdul Kadir
× Mohd, Fadzil bin Abdul Kadir× Yamakawa, Ai× Kodama, Dai× Tsuruoka, Shinji× Kawanaka, Hiroharu× Takase, Haruhiko× Uji, Yukitaka× Matsubara, Hisashi× Okuyama, Fumio |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Optical Coherence Tomography (OCT) image is very useful to the diagnosis and the follow up evaluation of the response to treatment using either medication or surgery, and it is an emerging medical imaging technology for performing high resolution cross-sectional images. In ophthalmology, this technology can provide 3D images of retinal architecture, and it is useful for identifying, monitoring, quantitatively assessing of retinal disease. Evaluations of quantitative information on retinal architecture especially on the abnormal parts are importance to diagnosis the degree of abnormal and to consider a treatment approach. This research proposes a new extraction method for the abnormal regions of retina from 3D OCT images using the combination of digital image processing methods. Our research objectives are extracting the border line of abnormal parts of 3D OCT retinal images. This research uses 128 2D OCT images about one retina of a patient, which is specified the part of macular by an ophthalmologist. We can extract some border lines of abnormal parts in OCT retinal images by using image processing techniques. |
|||||
書誌情報 |
Proceedings of the Second International Workshop on Regional Innovation Studies : (IWRIS2010) 号 2, p. 83-86, 発行日 2011-10-01 |
|||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Graduate School of Regional Innovation Studies, Mie University | |||||
資源タイプ(三重大) | ||||||