ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "348cf49b-bf4e-4cea-91ed-dc43d5cd09cc"}, "_deposit": {"created_by": 13, "id": "6448", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "6448"}, "status": "published"}, "_oai": {"id": "oai:mie-u.repo.nii.ac.jp:00006448", "sets": ["518"]}, "author_link": ["15055", "15056", "15057", "15058", "15059", "15060", "15061", "15062", "15063"], "item_4_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "86", "bibliographicPageStart": "83", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the Second International Workshop on Regional Innovation Studies :  (IWRIS2010)"}]}]}, "item_4_description_14": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_4_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Optical Coherence Tomography (OCT) image\nis very useful to the diagnosis and the follow up evaluation of\nthe response to treatment using either medication or surgery,\nand it is an emerging medical imaging technology for performing\nhigh resolution cross-sectional images. In ophthalmology,\nthis technology can provide 3D images of retinal architecture,\nand it is useful for identifying, monitoring, quantitatively assessing\nof retinal disease. Evaluations of quantitative information\non retinal architecture especially on the abnormal parts\nare importance to diagnosis the degree of abnormal and to\nconsider a treatment approach. This research proposes a new\nextraction method for the abnormal regions of retina from 3D\nOCT images using the combination of digital image processing\nmethods. Our research objectives are extracting the border\nline of abnormal parts of 3D OCT retinal images. This research\nuses 128 2D OCT images about one retina of a patient,\nwhich is specified the part of macular by an ophthalmologist.\nWe can extract some border lines of abnormal parts in OCT\nretinal images by using image processing techniques.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_30": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Graduate School of Regional Innovation Studies, Mie University"}]}, "item_4_text_65": {"attribute_name": "資源タイプ(三重大)", "attribute_value_mlt": [{"subitem_text_value": "Departmental Bulletin Paper / 紀要論文"}]}, "item_4_version_type_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mohd, Fadzil bin  Abdul Kadir", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15055", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamakawa, Ai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15056", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kodama, Dai", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15057", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuruoka, Shinji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15058", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawanaka, Hiroharu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15059", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takase, Haruhiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15060", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uji, Yukitaka", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15061", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsubara, Hisashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15062", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuyama, Fumio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "15063", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-02-18"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "60C15242.pdf", "filesize": [{"value": "545.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 545000.0, "url": {"label": "60C15242.pdf", "url": "https://mie-u.repo.nii.ac.jp/record/6448/files/60C15242.pdf"}, "version_id": "639fc5d4-d159-4b07-9ce5-4b8e0c4c690a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Optical coherence tomography (OCT)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image processing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image diagnosis system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "retinal layer structure", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image", "subitem_title_language": "en"}]}, "item_type_id": "4", "owner": "13", "path": ["518"], "permalink_uri": "http://hdl.handle.net/10076/11668", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-11-09"}, "publish_date": "2011-11-09", "publish_status": "0", "recid": "6448", "relation": {}, "relation_version_is_last": true, "title": ["Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image"], "weko_shared_id": -1}
  1. 60 地域イノベーション学研究科
  2. 60C 紀要
  3. Proceedings of the International Workshop on Regional Innovation Studies
  4. 2(2010)

Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image

http://hdl.handle.net/10076/11668
http://hdl.handle.net/10076/11668
09868a9f-0005-4c83-a842-15bbf1392da6
名前 / ファイル ライセンス アクション
60C15242.pdf 60C15242.pdf (545.0 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2011-11-09
タイトル
言語 en
タイトル Extraction Method of Abnormal Parts in Retinal Layers from Optical Coherence Tomography Image
言語
言語 eng
キーワード
主題Scheme Other
主題 Optical coherence tomography (OCT)
キーワード
主題Scheme Other
主題 image processing
キーワード
主題Scheme Other
主題 image diagnosis system
キーワード
主題Scheme Other
主題 retinal layer structure
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 Mohd, Fadzil bin Abdul Kadir

× Mohd, Fadzil bin Abdul Kadir

WEKO 15055

en Mohd, Fadzil bin Abdul Kadir

Search repository
Yamakawa, Ai

× Yamakawa, Ai

WEKO 15056

en Yamakawa, Ai

Search repository
Kodama, Dai

× Kodama, Dai

WEKO 15057

en Kodama, Dai

Search repository
Tsuruoka, Shinji

× Tsuruoka, Shinji

WEKO 15058

en Tsuruoka, Shinji

Search repository
Kawanaka, Hiroharu

× Kawanaka, Hiroharu

WEKO 15059

en Kawanaka, Hiroharu

Search repository
Takase, Haruhiko

× Takase, Haruhiko

WEKO 15060

en Takase, Haruhiko

Search repository
Uji, Yukitaka

× Uji, Yukitaka

WEKO 15061

en Uji, Yukitaka

Search repository
Matsubara, Hisashi

× Matsubara, Hisashi

WEKO 15062

en Matsubara, Hisashi

Search repository
Okuyama, Fumio

× Okuyama, Fumio

WEKO 15063

en Okuyama, Fumio

Search repository
抄録
内容記述タイプ Abstract
内容記述 Optical Coherence Tomography (OCT) image
is very useful to the diagnosis and the follow up evaluation of
the response to treatment using either medication or surgery,
and it is an emerging medical imaging technology for performing
high resolution cross-sectional images. In ophthalmology,
this technology can provide 3D images of retinal architecture,
and it is useful for identifying, monitoring, quantitatively assessing
of retinal disease. Evaluations of quantitative information
on retinal architecture especially on the abnormal parts
are importance to diagnosis the degree of abnormal and to
consider a treatment approach. This research proposes a new
extraction method for the abnormal regions of retina from 3D
OCT images using the combination of digital image processing
methods. Our research objectives are extracting the border
line of abnormal parts of 3D OCT retinal images. This research
uses 128 2D OCT images about one retina of a patient,
which is specified the part of macular by an ophthalmologist.
We can extract some border lines of abnormal parts in OCT
retinal images by using image processing techniques.
書誌情報 Proceedings of the Second International Workshop on Regional Innovation Studies : (IWRIS2010)

号 2, p. 83-86, 発行日 2011-10-01
フォーマット
内容記述タイプ Other
内容記述 application/pdf
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
出版者
出版者 Graduate School of Regional Innovation Studies, Mie University
資源タイプ(三重大)
Departmental Bulletin Paper / 紀要論文
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-19 15:56:24.217755
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3